Vapor retarders



In this section, a ceiling assembly separates the attic space above from the room interior below. If the building is located in Lewisville, Texas (hot-humid zone), where is the predicted location of condensation and what is the predicted condition of the gypsum board in this assembly? (Select 2 from the following)

A. outside face of vapor retarder
B. inside face of vapor retarder
C. gypsum board will be wet
D. gypsum board will be dry



Answer: A. and C. As Lewisville is a hot-humid location, expect the room interior to be cooled by air-conditioning. Kraft paper facing acts as a vapor retarder with predictable condensation on the outside face, but this is faced on both sides - so the gyp. board will be wet. The vapor retarder should only be located outside of the insulation or between the insulation and the ventilated attic space.

Visit the PPD-PDD page for more study resources!

Reference tip: read a paper about air vs vapor barriers here from conference session E11: Performance of the Building Enclosure of the 2008 Best 1 Conference BEST = Building Enclosure Science & Technology from National Institute of Building Sciences.

Comments

  1. Updated the links to the Building Enclosure paper & NIBS BEST Conferences...

    ReplyDelete

Post a Comment

Try These Too!

Bolted connections

What is the minimum spacing of bolts specified by AISC? and preferred spacing? A. 1 1/4 times the diameter of the bolt; 2 times preferred B. 1 3/4 times the diameter of the bolt; 2 1/4 times preferred C. 2 1/3 times the diameter of the bolt; 2 2/3 times preferred D. 2 2/3 times the diameter of the bolt; 3 times preferred E. 3 times the diameter of the bolt; 3.25 times preferred

Roof pitch

Which one of the following slopes in this illustration corresponds with an 8:12 pitch roof? A. 45° B. 36.87° C. 33.69° D. 26.57°

Floor receptacles

To qualify as one of the required power receptacles in a dwelling, according to NEC, what is the maximum distance from the wall that this recessed or surface-mounted floor receptacle close to an exterior wall may be? Answer Less than or equal to 18 inches. Additional requirements apply, such as approved floor box housing, cover... ARE 4.0 exam prep: BS