Fire-resistance rating requirements listed in IBC Table 601 list major building elements based on construction classification. Match these two criteria correctly, choose 2
A. Type IB = roof construction 1 1/2 hrs
B. Type IIB = exterior bearing walls 1 hr
C. Type IIIA = structural frame 1 hr
D. Type VB = floor construction 1 hr
E. Type IVHT = exterior bearing walls 2 hr
AnswerC. and E. are correct. HT = heavy timber.
ARE 4.0 exam prep: BDCS
Reference tip: Find the online version of Table 601 in this discussion paper here
A. Type IB = roof construction 1 1/2 hrs
B. Type IIB = exterior bearing walls 1 hr
C. Type IIIA = structural frame 1 hr
D. Type VB = floor construction 1 hr
E. Type IVHT = exterior bearing walls 2 hr
AnswerC. and E. are correct. HT = heavy timber.
ARE 4.0 exam prep: BDCS
Reference tip: Find the online version of Table 601 in this discussion paper here
Link takes you to a page not found, just thought I let you know.
ReplyDeleteThank you very much for all the useful information.
updated to new link. thanks!
ReplyDelete