Skip to main content

ADA door clearance


What is the minimum clear depth and width for a push side / hinge side approach of this swinging door if it has both latch and closer?

AnswerDepth = 48, Width = 54, depth would be 42 without latch and closer
ARE 4.0 exam prep: CDS

Comments

  1. Thank you for all the knowledge you distribute,Good post. I was very interested in the article
    Sliding Glass Door Window Replacement
    Windows And Doors Phoenix

    ReplyDelete

Post a Comment

Try These Too!

Building Efficiency

Convert the usable area of classrooms planned with medium efficiency level of new construction to the gross building area given the following model factors: Net Assignable Square Feet: 10,000, Space Factor: 1.5, Building Efficiency Ratio: 67%

Spec coordination

In case there is a discrepancy between specifications and the drawings, which takes precedence? Answer Neither, A201 considers these - quote - complementary and what is required by one shall be binding as if required by all.- unquote. ARE 4.0 exam prep: CDS

Footing cross-section

When the thickness of a foundation wall = 6", the cross-sectional proportions in this image are appropriate for which of the following: A. a footing supported on clay soil B. light frame construction supporting one floor and one roof C. allowable bearing capacity of foundation soil is low in relation to building loads D. when a continuous footing is required Answer B. light frame construction supporting one floor and one roof (in accordance with Table 1805.4.2) ARE 4.0 exam prep: PPP