Skip to main content

Orienting the building

Although exact angles differ by the 4 major climatic regions, what is the optimum orientation for a rectangular building to maximize solar heat gain in winter months, minimize solar heat gain in summer months and minimize exposure to winter winds?
A. Long side facing east, B. Short side oriented east-west, C. Long side oriented east-west, D. Short side facing north




Answer is C. Long side oriented east-west.

For more exam resources see the PPD-PDD page

Comments

Try These Too!

Calculate Luminance

A typical 60-watt standard frosted incandescent bulb outputs 890 lumens for an efficacy ratio of about 15 lumens per watt. As an A19, its shape is spherical. What is the its calculated luminance? A. 25,115 cd/in² B. 25.115 cd/ft² C. 25,115 cd/m² D. Indeterminate, missing variable. Answer If 1 candela (cd) = 4 ∏ lumens (lm), 890 x 1cd/4∏ = 71 cd, A19 = 19/8 = 2.375 in or 60mm diameter (= 30mm radius), L = intensity / projected area, 71 cd / ∏ r² = 71/ 3.14 x (.03m)² = 25,115 cd/m² ARE 4.0 exam prep: BS

Characteristics of form

Which example illustrates a regular ordering of elements producing RHYTHM? A B C D Answer Answer is C. A = proportion, B = symmetry, D = balance ARE 4.0 exam prep: PPP

Roof pitch