Calculating daylight

The daylight factor method (CIE - E.U.) calculates how much daylight reaches any location in a room assuming overcast/diffuse conditions; and can account for corner windows, which cannot be accounted for using the lumen method (IES - U.S.). When 2,200 fc is measured on the ground outside, what is the resulting illumination level if one end of a room has a daylight factor of 2?



Answer is 2200 fc x 0.02 = 44 fc. DF is a percentage of the light available outside.
are-review.blogspot.com

Comments

Try These Too!

Building Efficiency

Convert the usable area of classrooms planned with medium efficiency level of new construction to the gross building area given the following model factors: Net Assignable Square Feet: 10,000, Space Factor: 1.5, Building Efficiency Ratio: 67%

Overimprovement

While underimprovement describes property that is not being put to its highest and best use (reducing its value), when does overimprovement apply?

Construction type

Fire-resistance rating requirements listed in IBC Table 601 list major building elements based on construction classification. Match these two criteria correctly, choose 2 A. Type IB = roof construction 1 1/2 hrs B. Type IIB = exterior bearing walls 1 hr C. Type IIIA = structural frame 1 hr D. Type VB = floor construction 1 hr E. Type IVHT = exterior bearing walls 2 hr Answer C. and E. are correct. HT = heavy timber. ARE 4.0 exam prep: BDCS Reference tip:  Find the online version of Table 601 in this discussion paper here