Means of egress

What is the minimum percentage of the number and capacity of the exit enclosures for a building that must connect to the public way without intervening spaces?
A. 20%, B. 35%, C. 40%, D. 50%, E. 60%

D. 50% is correct.
Exit discharge can pass through intervening spaces (such as with a fully-sprinklered lobby) for up to 50% of the number and capacity of exits.
are-review.blogspot.com

Comments

Try These Too!

Bolted connections

What is the minimum spacing of bolts specified by AISC? and preferred spacing? A. 1 1/4 times the diameter of the bolt; 2 times preferred B. 1 3/4 times the diameter of the bolt; 2 1/4 times preferred C. 2 1/3 times the diameter of the bolt; 2 2/3 times preferred D. 2 2/3 times the diameter of the bolt; 3 times preferred E. 3 times the diameter of the bolt; 3.25 times preferred

Building Efficiency

Convert the usable area of classrooms planned with medium efficiency level of new construction to the gross building area given the following model factors: Net Assignable Square Feet: 10,000, Space Factor: 1.5, Building Efficiency Ratio: 67%

Submittals

Which of the following are defined as product data (in the general conditions A201), "furnished by the contractor to illustrate materials or equipment for some portion of the Work." I. diagrams II. physical examples III. performance charts IV. instructions V. drawings Answer All except V. drawings, which are specifically Shop Drawings, and II. physical examples, which are called Samples.