What is the minimum percentage of the number and capacity of the exit enclosures for a building that must connect to the public way without intervening spaces?
A. 20%, B. 35%, C. 40%, D. 50%, E. 60%

D. 50% is correct.
Exit discharge can pass through intervening spaces (such as with a fully-sprinklered lobby) for up to 50% of the number and capacity of exits.
are-review.blogspot.com

Comments

Try These Too!

Elevator bank layouts

An office building has an elevator bank with 4 elevators where 2 cabs side-by-side are arranged opposite the other 2. Each of the elevators is 3500-pound capacity with an interior cab dimension of 6'8" x 5'4". What is the recommended corridor width at this group? A. 8 feet B. 9 feet C. 11 feet D. 12 feet Answer C. 11 feet. At 1.5-2 times the car depth (5'4), this could be a range, but 10 feet is a minimum for groups of 4 or more. Therefore C is the best choice. ARE 4.0 exam prep: BDCS

Bolted connections

What is the minimum spacing of bolts specified by AISC? and preferred spacing? A. 1 1/4 times the diameter of the bolt; 2 times preferred B. 1 3/4 times the diameter of the bolt; 2 1/4 times preferred C. 2 1/3 times the diameter of the bolt; 2 2/3 times preferred D. 2 2/3 times the diameter of the bolt; 3 times preferred E. 3 times the diameter of the bolt; 3.25 times preferred

Fire detection

Which of the following detector types can detect smoke or a smoldering fire that has not yet burst into flames? A. Ionization B. Rise-of-temperature C. Photoelectric D. Flame detectors