What is the minimum percentage of the number and capacity of the exit enclosures for a building that must connect to the public way without intervening spaces?
A. 20%, B. 35%, C. 40%, D. 50%, E. 60%

D. 50% is correct.
Exit discharge can pass through intervening spaces (such as with a fully-sprinklered lobby) for up to 50% of the number and capacity of exits.
are-review.blogspot.com

Comments

Try These Too!

Overimprovement

While underimprovement describes property that is not being put to its highest and best use (reducing its value), when does overimprovement apply?

Construction type

Fire-resistance rating requirements listed in IBC Table 601 list major building elements based on construction classification. Match these two criteria correctly, choose 2 A. Type IB = roof construction 1 1/2 hrs B. Type IIB = exterior bearing walls 1 hr C. Type IIIA = structural frame 1 hr D. Type VB = floor construction 1 hr E. Type IVHT = exterior bearing walls 2 hr Answer C. and E. are correct. HT = heavy timber. ARE 4.0 exam prep: BDCS Reference tip:  Find the online version of Table 601 in this discussion paper here