It has been determined that the calculated runoff of a site development will exceed the existing municipal storm sewer's capacity. What is the most likely solution to be proposed?
A. create a larger leach field
B. create a retention pond
C. create a detention pond
D. recalculate using a storm event period of smaller magnitude


Answer is C. create a detention pond, which serves as a temporary holding pond for the site runoff, until it drains at a controlled rate to the sewer system.

B. will hold the runoff indefinitely, A. is only applicable to a septic system, D. is set by local regulations and practice.
are-review.blogspot.com

Comments

Try These Too!

Building Efficiency

Convert the usable area of classrooms planned with medium efficiency level of new construction to the gross building area given the following model factors: Net Assignable Square Feet: 10,000, Space Factor: 1.5, Building Efficiency Ratio: 67%

Spec coordination

In case there is a discrepancy between specifications and the drawings, which takes precedence? Answer Neither, A201 considers these - quote - complementary and what is required by one shall be binding as if required by all.- unquote. ARE 4.0 exam prep: CDS

Footing cross-section

When the thickness of a foundation wall = 6", the cross-sectional proportions in this image are appropriate for which of the following: A. a footing supported on clay soil B. light frame construction supporting one floor and one roof C. allowable bearing capacity of foundation soil is low in relation to building loads D. when a continuous footing is required Answer B. light frame construction supporting one floor and one roof (in accordance with Table 1805.4.2) ARE 4.0 exam prep: PPP