Group replacement

Select the most correct statement for
Group Replacement System
A. Used in stadium installation
B. Desirable for lower installation costs
C. Following burnout, system is used when lamps are replaced
D. Extends lamp life by operating under voltage

AnswerD. Extends lamp life by operating under voltage. Group replacement is an advantageous maintenance scheme for large areas of lighting with no interim relamping necessary. Individual burnouts are ignored until a critical number is reached. C. refers to spot replacement, relamping when individual lamps no longer function.
ARE 4.0 exam prep: BS

Comments

Try These Too!

Calculate Luminance

A typical 60-watt standard frosted incandescent bulb outputs 890 lumens for an efficacy ratio of about 15 lumens per watt. As an A19, its shape is spherical. What is the its calculated luminance? A. 25,115 cd/in² B. 25.115 cd/ft² C. 25,115 cd/m² D. Indeterminate, missing variable. Answer If 1 candela (cd) = 4 ∏ lumens (lm), 890 x 1cd/4∏ = 71 cd, A19 = 19/8 = 2.375 in or 60mm diameter (= 30mm radius), L = intensity / projected area, 71 cd / ∏ r² = 71/ 3.14 x (.03m)² = 25,115 cd/m² ARE 4.0 exam prep: BS

Characteristics of form

Which example illustrates a regular ordering of elements producing RHYTHM? A B C D Answer Answer is C. A = proportion, B = symmetry, D = balance ARE 4.0 exam prep: PPP

Roof pitch

Which one of the following slopes in this illustration corresponds with an 8:12 pitch roof? A. 45° B. 36.87° C. 33.69° D. 26.57°