Required cooling capacity

Roughly 3 tons of cooling is being estimated for a 2,700 square foot residential building. Choose 2 locations in which this estimation can be applied.

A. Rhode Island
B. Ontario, Canada
C. Nevada
D. North Carolina

AnswerA and B are the best answers. As a rule of thumb, 1 ton will cool 800-1000 sf
in the northern US and Canada, but only 450-700 sf in the southern US. Thus, 2700 sf divided by 900 sf per ton = 3 tons.

ARE 4.0 exam prep: BS

Comments

Try These Too!

Building Efficiency

Convert the usable area of classrooms planned with medium efficiency level of new construction to the gross building area given the following model factors: Net Assignable Square Feet: 10,000, Space Factor: 1.5, Building Efficiency Ratio: 67%

Spec coordination

In case there is a discrepancy between specifications and the drawings, which takes precedence? Answer Neither, A201 considers these - quote - complementary and what is required by one shall be binding as if required by all.- unquote. ARE 4.0 exam prep: CDS

Footing cross-section

When the thickness of a foundation wall = 6", the cross-sectional proportions in this image are appropriate for which of the following: A. a footing supported on clay soil B. light frame construction supporting one floor and one roof C. allowable bearing capacity of foundation soil is low in relation to building loads D. when a continuous footing is required Answer B. light frame construction supporting one floor and one roof (in accordance with Table 1805.4.2) ARE 4.0 exam prep: PPP