Required cooling capacity

Roughly 3 tons of cooling is being estimated for a 2,700 square foot residential building. Choose 2 locations in which this estimation can be applied.

A. Rhode Island
B. Ontario, Canada
C. Nevada
D. North Carolina

AnswerA and B are the best answers. As a rule of thumb, 1 ton will cool 800-1000 sf
in the northern US and Canada, but only 450-700 sf in the southern US. Thus, 2700 sf divided by 900 sf per ton = 3 tons.

ARE 4.0 exam prep: BS

Comments

Try These Too!

Calculate Luminance

A typical 60-watt standard frosted incandescent bulb outputs 890 lumens for an efficacy ratio of about 15 lumens per watt. As an A19, its shape is spherical. What is the its calculated luminance? A. 25,115 cd/in² B. 25.115 cd/ft² C. 25,115 cd/m² D. Indeterminate, missing variable. Answer If 1 candela (cd) = 4 ∏ lumens (lm), 890 x 1cd/4∏ = 71 cd, A19 = 19/8 = 2.375 in or 60mm diameter (= 30mm radius), L = intensity / projected area, 71 cd / ∏ r² = 71/ 3.14 x (.03m)² = 25,115 cd/m² ARE 4.0 exam prep: BS