Exits from a room

In a 20ft by 30ft sprinklered space requiring two exits, what is the minimum distance that one exit must be separated from the other?
A. 10ft
B. 12ft
C. 14ft
D. 16ft

AnswerB. 12ft. For a sprinklered space, take the diagonal distance of the space times one third for the minimum separation between exits.
ARE 4.0 exam prep: CDS

Comments

Try These Too!

Fire detection

Which of the following detector types can detect smoke or a smoldering fire that has not yet burst into flames? A. Ionization B. Rise-of-temperature C. Photoelectric D. Flame detectors

Risk management

How does an owner provide a financial safeguard for the following situations: - unanticipated price escalation of a particular product - an architect’s omission of flashing in the construction documents - a necessary change during construction, modifying the project’s scope. A. Allowance B. Alternates C. Contingency D. Escalation Answer C. Contingency is an amount, usually a percentage, that is part of the project budget to offset changes in the scope of the project, unknown conditions, and gaps/oversights in the documents. ARE 4.0 exam prep: PPP