Skip to main content

Daylighting


Examining the daylighting potential in a project, determine from this illustration the effective depth of the room which will receive acceptable daylight illumination.

A. 8'-6"
B. 10'-2"
C. 11'-6"
D. 12'-9"

AnswerD. 12 ft 9 in. Take the head height above the floor times 1.5 for the effective depth of illumination. If using a light shelf, daylight could penetrate into the room a distance of 2 to 2.5 times the head height.
ARE 4.0 exam prep: BS

Comments

Try These Too!

Fire detection

Which of the following detector types can detect smoke or a smoldering fire that has not yet burst into flames? A. Ionization B. Rise-of-temperature C. Photoelectric D. Flame detectors

Calculate beam reaction

Find the reactions indicated in the beam diagram. ( ∑M = 0 ; Moment sum of loads and resisting reaction is equal to zero.)