Water supply

A loft tank in the house is connected to the outdoor pool on the hillside. If the pool elevation is higher than the supply tank, dirty water will be siphoned down to the house. What means can prevent the potential contamination of a potable water system?

A. reduced principle assembly (RP)
B. air gap
C. double check valve assembly (DC)
D. pressure vacuum breaker (PVB)
E. none of the above
F. all of the above
AnswerF. all of the above - are backflow prevention methods, but in this case a mechanical backflow preventer is the proper mechanism required. A/C/D are principal types of backflow prevention devices.
ARE 4.0 exam prep: BS

Comments

Try These Too!

Moisture content in wood

The amount of shrinkage, weight, strength, and withdrawal resistance of nails is affected by the moisture content in wood. Wood that is grademarked kiln dry has a maximum moisture content of: A. 15% B. 19% C. 25% D. 30% Answer A. 15%. Dry lumber moisture content cannot exceed 19%. ARE 4.0 exam prep: SS

Cantilevered beam

The bending moment in a cantilevered beam is negative. Which of the following statements are true? A. the top fibers are in compression B. the bottom fibers are in compression C. rebar placement should be either at the top or the bottom D. gravity loads are not a factor for negative moment Answer B. the bottom fibers are in compression in a cantilevered beam, so top fibers are in tension which requires rebar placement at the top to resist tension. ARE 4.0 exam prep: SS

Fire-alarm & detection systems

In an atrium connecting 2 or more stories, what device types are generally required per section 907.2.13 of the International Fire Code (IFC)? Answer Fire alarm activated by automatic alarm, fire flow or manual alarm. Further, in Group A, E or M occupancies, emergency voice / alarm communication system is required per 907.2.12.2 (High-rise buildings). ARE 4.0 exam prep: BS