Plumbing equipment provisions

In many local codes, water heater tanks are required to be braced, strapped or anchored to the structure, maintaining less than 1-2 inches of space between the wall and the equipment. Which of the following are most likely locations for such provisions to apply? Choose 3
A. California
B. Alaska
C. Oregon
D. Florida
E. Wisconsin

AnswerA, B & C. These types of provisions are required for equipment to resist horizontal displacement due to earthquake motion. Non-structural building systems and equipment are a significant hazard during earthquake events: breaking gas lines, flooding, igniting fires, enabling electrocution, causing high monetary damage.
ARE 4.0 exam prep: BS

Comments

Try These Too!

Building Efficiency

Convert the usable area of classrooms planned with medium efficiency level of new construction to the gross building area given the following model factors: Net Assignable Square Feet: 10,000, Space Factor: 1.5, Building Efficiency Ratio: 67%

Construction type

Fire-resistance rating requirements listed in IBC Table 601 list major building elements based on construction classification. Match these two criteria correctly, choose 2 A. Type IB = roof construction 1 1/2 hrs B. Type IIB = exterior bearing walls 1 hr C. Type IIIA = structural frame 1 hr D. Type VB = floor construction 1 hr E. Type IVHT = exterior bearing walls 2 hr Answer C. and E. are correct. HT = heavy timber. ARE 4.0 exam prep: BDCS Reference tip:  Find the online version of Table 601 in this discussion paper here

Vapor retarders

In this section, a ceiling assembly separates the attic space above from the room interior below. If the building is located in Lewisville, Texas (hot-humid zone), where is the predicted location of condensation and what is the predicted condition of the gypsum board in this assembly? (Select 2 from the following) A. outside face of vapor retarder B. inside face of vapor retarder C. gypsum board will be wet D. gypsum board will be dry