Foundation piles 1

Four 12 inch diameter piles (each of whose frictional capacity is 300 psf) support a column carrying 120 kips total load.

What is the frictional area required for each pile?
A. 30 sf
B. 40 sf
C. 70 sf
D. 100 sf

AnswerD. 100sf. Each pile supports 30 kips (120 kips / 4), when divided by the frictional capacity (30 kips / 0.300 kips per sf = 100 sf) gives the required frictional area 100 sf


ARE 4.0 exam prep: SS

Comments

Try These Too!

Fire detection

Which of the following detector types can detect smoke or a smoldering fire that has not yet burst into flames? A. Ionization B. Rise-of-temperature C. Photoelectric D. Flame detectors

Required cooling capacity

Roughly 3 tons of cooling is being estimated for a 2,700 square foot residential building. Choose 2 locations in which this estimation can be applied. A. Rhode Island B. Ontario, Canada C. Nevada D. North Carolina Answer A and B are the best answers. As a rule of thumb, 1 ton will cool 800-1000 sf in the northern US and Canada, but only 450-700 sf in the southern US. Thus, 2700 sf divided by 900 sf per ton = 3 tons. ARE 4.0 exam prep: BS