Table 601

IBC Table 601 gives the required fire-resistance ratings in hours. Which primary building elements constitute the structural frame specified by these requirements?
I. lateral bracing, II. roof framing, III. columns, IV. stairways, V. girders, beams, VI trusses
A. III, V, VI,  B. I, III, V,  C. I, II, III, V, VI,  D. II, III, V


A. is correct. Only major elements that frame directly into the columns are included as structural frame + designed to carry gravity loads. II. is a secondary element. I. does not meet this criteria, but is usually still fire-protected.

are-review.blogspot.com

Comments

Try These Too!

Building Efficiency

Convert the usable area of classrooms planned with medium efficiency level of new construction to the gross building area given the following model factors: Net Assignable Square Feet: 10,000, Space Factor: 1.5, Building Efficiency Ratio: 67%

Spec coordination

In case there is a discrepancy between specifications and the drawings, which takes precedence? Answer Neither, A201 considers these - quote - complementary and what is required by one shall be binding as if required by all.- unquote. ARE 4.0 exam prep: CDS