Skip to main content

Notches in sawn lumber

Without calculating vertical shear, some prescriptive guidance in the code exists regarding notched beams (which as a general rule should be avoided). If a 4 x 12 wood beam is notched at a supporting end, which of the following is the maximum depth it can be notched?
A. 1 3/4 inches
B. 2 inches
C. 2 1/2 inches
D. 2 3/4 inches
E. 3 inches

Answer"D. 2 3/4 inches does not exceed the maximum one-fourth the beam depth allowable by IBC. The actual depth of a 4x12 is 11.25 inches.

ARE 4.0 exam prep: SS

Comments

Try These Too!

Fire detection

Which of the following detector types can detect smoke or a smoldering fire that has not yet burst into flames? A. Ionization B. Rise-of-temperature C. Photoelectric D. Flame detectors

Risk management

How does an owner provide a financial safeguard for the following situations: - unanticipated price escalation of a particular product - an architect’s omission of flashing in the construction documents - a necessary change during construction, modifying the project’s scope. A. Allowance B. Alternates C. Contingency D. Escalation Answer C. Contingency is an amount, usually a percentage, that is part of the project budget to offset changes in the scope of the project, unknown conditions, and gaps/oversights in the documents. ARE 4.0 exam prep: PPP