Notches in sawn lumber

Without calculating vertical shear, some prescriptive guidance in the code exists regarding notched beams (which as a general rule should be avoided). If a 4 x 12 wood beam is notched at a supporting end, which of the following is the maximum depth it can be notched?
A. 1 3/4 inches
B. 2 inches
C. 2 1/2 inches
D. 2 3/4 inches
E. 3 inches

Answer"D. 2 3/4 inches does not exceed the maximum one-fourth the beam depth allowable by IBC. The actual depth of a 4x12 is 11.25 inches.

ARE 4.0 exam prep: SS

Comments

Try These Too!

Overimprovement

While underimprovement describes property that is not being put to its highest and best use (reducing its value), when does overimprovement apply?

Change in services

An owner may authorize a change in services for which a written scope of duties is attached to the owner-architect contract, to provide a higher degree of monitoring or observing work on site than expected under basic construction phase services for architect's site visits. What is this role and when does it occur?