Notches in sawn lumber

Without calculating vertical shear, some prescriptive guidance in the code exists regarding notched beams (which as a general rule should be avoided). If a 4 x 12 wood beam is notched at a supporting end, which of the following is the maximum depth it can be notched?
A. 1 3/4 inches
B. 2 inches
C. 2 1/2 inches
D. 2 3/4 inches
E. 3 inches

Answer"D. 2 3/4 inches does not exceed the maximum one-fourth the beam depth allowable by IBC. The actual depth of a 4x12 is 11.25 inches.

ARE 4.0 exam prep: SS

Comments

Try These Too!

Townships double post!

How many sections are contained within a township? Answer 36 (each is 1 mile square) What are the dimensions of 1/2 of a township? H & W Answer 18 miles square (3x6 sections) ARE 4.0 exam prep: SPD

Radius of gyration

For column design, the radius of gyration incorporates area and the moment of inertia. This value represents the resistance of a cross-section to buckling, which in columns happens under a load parallel to its lesser dimension. The slenderness ratio is the ratio of a column's effective length (modified by K-value to account for its end conditions) to its least radius of gyration. For a W12x16 A36 steel column with a least radius of gyration of 0.773, whose ends are both free to rotate but fixed in translation (K=1), what is it's slenderness ratio? Answer Kl/r = (1)(12feet)(12in/ft) / 0.773 = 186.3 ARE 4.0 exam prep: SS

Parking units

What are the car stall dimensions for a compact car? Answer A compact car stall size can be set by each municipality and therefore varies. Generally it is 7ft 6in wide by 15ft 0in long. However, in Fresno CA it's 8 1/2ft x 16ft and according to an Iowa urban design manual, it's 7ft 6in by 16ft. ARE 4.0 exam prep: SPD