Notches in sawn lumber

Without calculating vertical shear, some prescriptive guidance in the code exists regarding notched beams (which as a general rule should be avoided). If a 4 x 12 wood beam is notched at a supporting end, which of the following is the maximum depth it can be notched?
A. 1 3/4 inches
B. 2 inches
C. 2 1/2 inches
D. 2 3/4 inches
E. 3 inches

Answer"D. 2 3/4 inches does not exceed the maximum one-fourth the beam depth allowable by IBC. The actual depth of a 4x12 is 11.25 inches.

ARE 4.0 exam prep: SS

Comments

Try These Too!

Vertical louvers

On which elevations of a building are vertical louvers generally more effective? Select 2 A. East B. South C. West D. North Answer A. East and C. West (answer applies for northern hemisphere) ARE 4.0 exam prep: SPD

Friction loss

Friction loss or static head in sizing of air ducts is given in this expression of units: A. pounds per square inch B. inches of water per 100 feet C. inches of refrigerant per 100 feet D. inches of water per foot Answer B. inches of water per 100 feet ARE 4.0 exam prep: BS

Joint ventures

Which AIA document series includes agreements for joint ventures? A. A-series B. B-series C. C-series D. D-series E. G-series Answer C. C-series covers architect/consultant documents including joint ventures.