Skip to main content

Fire-resistant paints

Intumescent paints are often used to protect exposed steel, making it unnecessary to enclose the structure with fire-rated assemblies and saving valuable interior space. Why must special care be taken with construction tolerances around all structural elements using intumescent paints?

AnswerIn a fire, the paint intumesces and expands to protect the material. Adequate clearance must be taken into account to ensure proper fire-resistance will be maintained.

ARE 4.0 exam prep: BDCS

Comments

Try These Too!

Building Efficiency

Convert the usable area of classrooms planned with medium efficiency level of new construction to the gross building area given the following model factors: Net Assignable Square Feet: 10,000, Space Factor: 1.5, Building Efficiency Ratio: 67%

Deflection: steel or wood

For EITHER steel or wood beams, a question that asks for the allowable deflection limit (maximum) for live loads only requires which of the following equations? A. L/240 B. L/360 C. ∆ = 5wl⁴ / 384EI D. ∆ = 5Wl³ / 384EI Answer B. L/360 or span in inches divided by 360. ARE 4.0 exam prep: SS Note on calculations: From posted discussions on AREforum , memorization of most equations is not advised. However, even when the equation may be available in in-exam reference, selection of the appropriate equation requires correct identification.

Facility parking

A new office complex is being planned, which is required to include 162 parking spaces. In addition to the parking spaces, allow for related driveways and walkways to estimate the area of the parking lot that would satisfy this number of spaces. A. 1.0 acres B. 1.5 acres C. 1.75 acres D. 2.0 acres Answer B. 1.5 acres. Multiply the required parking spaces by 400 sf per car (1 acre = 43,560 sf). If walkways are not required, use 300 sf per car. ARE 4.0 exam prep: SPD