Skip to main content

ADA door clearance


What is the minimum clear depth and width for a push side / hinge side approach of this swinging door if it has both latch and closer?

AnswerDepth = 48, Width = 54, depth would be 42 without latch and closer
ARE 4.0 exam prep: CDS

Comments

  1. Thank you for all the knowledge you distribute,Good post. I was very interested in the article
    Sliding Glass Door Window Replacement
    Windows And Doors Phoenix

    ReplyDelete

Post a Comment

Try These Too!

Imageability

Select 5 components that contribute to imageability , Lynch's concept that posits that a highly imageable city is readily understandable and distinct. A. districts B. social structure C. edge D. landmark E. nodes F. overlapping systems G. paths H. legibility Answer A, C, D, E, G are components that contribute to defining imageability. ARE 4.0 exam prep: PPP

Interior Glazing

Safety glazing (tempered glass, laminated glass or impact resistant plastic) is not required at this interior window (18sf glazed area). Which of these satisfies conditions for using non-safety glazing? A. Within 36 inches horizontally of a walking surface B. Bottom edge is less than 60" above the plane of the adjacent walking surface C. 1 1/2 in protective bar between 34 and 38 inches on accessible side D. Exposed area of the pane is greater than 9 sf Answer C. 1 1/2 inch protective bar between 34-38 inches on accessible side. In this case, safety glazing is not required. ARE 4.0 exam prep: BDCS

Bolted connections

What is the minimum spacing of bolts specified by AISC? and preferred spacing? A. 1 1/4 times the diameter of the bolt; 2 times preferred B. 1 3/4 times the diameter of the bolt; 2 1/4 times preferred C. 2 1/3 times the diameter of the bolt; 2 2/3 times preferred D. 2 2/3 times the diameter of the bolt; 3 times preferred E. 3 times the diameter of the bolt; 3.25 times preferred