Exit discharge

A fully-sprinklered lobby may serve as the final portion of the means of egress when additional specific conditions are met - connects to a free and unobstructed way to the exterior, entire level of discharge is separated by same fire rated fire-resistive construction from the area below.
Most significantly, what condition must be met regarding occupant load & capacity of the exit?

AnswerExit discharge through intervening spaces is only possible for up to 50% of the number & capacity of the exit enclosures for the building. Thus, the other 50% must connect to the public way without intervening spaces.
ARE 4.0 exam prep: BDCS

Comments

Try These Too!

Vertical louvers

On which elevations of a building are vertical louvers generally more effective? Select 2 A. East B. South C. West D. North Answer A. East and C. West (answer applies for northern hemisphere) ARE 4.0 exam prep: SPD

Friction loss

Friction loss or static head in sizing of air ducts is given in this expression of units: A. pounds per square inch B. inches of water per 100 feet C. inches of refrigerant per 100 feet D. inches of water per foot Answer B. inches of water per 100 feet ARE 4.0 exam prep: BS

Joint ventures

Which AIA document series includes agreements for joint ventures? A. A-series B. B-series C. C-series D. D-series E. G-series Answer C. C-series covers architect/consultant documents including joint ventures.