Skip to main content

Drinking fountains

A 4-story law school building with a 250 occupant capacity has drinking fountains in the corridor of each floor. According to IBC special occupancy provisions, how many fountains are required in total?

Answer8 (4 for standing persons, 4 at a low elevation for wheelchairs). 50% must be accessible on floors where they are provided, even on floors that are not required to be accessible (1109.5).

Comments

Try These Too!

Building Efficiency

Convert the usable area of classrooms planned with medium efficiency level of new construction to the gross building area given the following model factors: Net Assignable Square Feet: 10,000, Space Factor: 1.5, Building Efficiency Ratio: 67%

Spec coordination

In case there is a discrepancy between specifications and the drawings, which takes precedence? Answer Neither, A201 considers these - quote - complementary and what is required by one shall be binding as if required by all.- unquote. ARE 4.0 exam prep: CDS

Shoring

A slurry wall is a narrow trench filled with a slurry mixture composed of bentonite clay and water, enabling it to resist pressure from the surrounding earth. What type temporary support is this? A. Bracing B. Sheeting C. Underpinning Answer B. It is a type of sheeting. ARE 4.0 exam prep: SPD