Drinking fountains

A 4-story law school building with a 250 occupant capacity has drinking fountains in the corridor of each floor. According to IBC special occupancy provisions, how many fountains are required in total?

Answer8 (4 for standing persons, 4 at a low elevation for wheelchairs). 50% must be accessible on floors where they are provided, even on floors that are not required to be accessible (1109.5).

Comments

Try These Too!

Calculate Luminance

A typical 60-watt standard frosted incandescent bulb outputs 890 lumens for an efficacy ratio of about 15 lumens per watt. As an A19, its shape is spherical. What is the its calculated luminance? A. 25,115 cd/in² B. 25.115 cd/ft² C. 25,115 cd/m² D. Indeterminate, missing variable. Answer If 1 candela (cd) = 4 ∏ lumens (lm), 890 x 1cd/4∏ = 71 cd, A19 = 19/8 = 2.375 in or 60mm diameter (= 30mm radius), L = intensity / projected area, 71 cd / ∏ r² = 71/ 3.14 x (.03m)² = 25,115 cd/m² ARE 4.0 exam prep: BS

Bolted connections

What is the minimum spacing of bolts specified by AISC? and preferred spacing? A. 1 1/4 times the diameter of the bolt; 2 times preferred B. 1 3/4 times the diameter of the bolt; 2 1/4 times preferred C. 2 1/3 times the diameter of the bolt; 2 2/3 times preferred D. 2 2/3 times the diameter of the bolt; 3 times preferred E. 3 times the diameter of the bolt; 3.25 times preferred

Concrete form ties

Unless stainless steel ties are specified, ACI (American Concrete Institute) recommends patching, partially filling or plugging the finished depression / holes left by form ties in the concrete surface. Why?