Wood: Duration of load


Design values of wood providing allowable design loads based on the normal duration of load are based on what length of time?
A. 3 years
B. 5 years
C. 10 years
D. 20 years




C. 10 years is considered the normal duration of loading. Shorter loading durations will increase the allowable unit stresses according to prescribed percentages.
are-review.blogspot.com

Comments

Try These Too!

Calculate Luminance

A typical 60-watt standard frosted incandescent bulb outputs 890 lumens for an efficacy ratio of about 15 lumens per watt. As an A19, its shape is spherical. What is the its calculated luminance? A. 25,115 cd/in² B. 25.115 cd/ft² C. 25,115 cd/m² D. Indeterminate, missing variable. Answer If 1 candela (cd) = 4 ∏ lumens (lm), 890 x 1cd/4∏ = 71 cd, A19 = 19/8 = 2.375 in or 60mm diameter (= 30mm radius), L = intensity / projected area, 71 cd / ∏ r² = 71/ 3.14 x (.03m)² = 25,115 cd/m² ARE 4.0 exam prep: BS