Skip to main content

Submittals

Which of the following are defined as product data (in the general conditions A201), "furnished by the contractor to illustrate materials or equipment for some portion of the Work."
I. diagrams
II. physical examples
III. performance charts
IV. instructions
V. drawings

AnswerAll except V. drawings, which are specifically Shop Drawings, and II. physical examples, which are called Samples.

Comments

Try These Too!

Structural forces

Choose a term that best identifies the type of force shown in this diagram - A. collinear B. concurrent C. nonconcurrent D. noncoplanar

Roof pitch

Which one of the following slopes in this illustration corresponds with an 8:12 pitch roof? A. 45° B. 36.87° C. 33.69° D. 26.57°

Bolted connections

What is the minimum spacing of bolts specified by AISC? and preferred spacing? A. 1 1/4 times the diameter of the bolt; 2 times preferred B. 1 3/4 times the diameter of the bolt; 2 1/4 times preferred C. 2 1/3 times the diameter of the bolt; 2 2/3 times preferred D. 2 2/3 times the diameter of the bolt; 3 times preferred E. 3 times the diameter of the bolt; 3.25 times preferred