Skip to main content

Important Factors Classification

According to IBC's classification of buildings and other structures for importance factors, which of the following occupancy categories include hospitals and other health care facilities having surgery or emergency treatment facilities?

A. I
B. II
C. III
D. IV
AnswerIV. gives an importance factor I of 1.5 for seismic, 1.2 for snow, 1.15 for wind. These buildings are designed as essential facilities, representing the greatest hazard to human life in the event of failure.

ARE 4.0 exam prep: SS

Comments

Try These Too!

Wood stairs

In wood stair construction, what is the difference between a carriage and a stringer?! Answer A carriage is the principle support for the treads and risers, whereas the stringer is the finish member (face) that treads and risers terminate against. ARE 4.0 exam prep: BDCS

Bolted connections

What is the minimum spacing of bolts specified by AISC? and preferred spacing? A. 1 1/4 times the diameter of the bolt; 2 times preferred B. 1 3/4 times the diameter of the bolt; 2 1/4 times preferred C. 2 1/3 times the diameter of the bolt; 2 2/3 times preferred D. 2 2/3 times the diameter of the bolt; 3 times preferred E. 3 times the diameter of the bolt; 3.25 times preferred

Brick bonds

What distinguishes the English Bond pattern from the Dutch Bond pattern in this image? Answer In the English Bond, stretchers are aligned; In the Dutch (cross), stretchers move by a half each course (not aligned). ARE 4.0 exam prep: BDCS