Exit access

In a building that requires two separate exits, the exits must be located to minimize the chance that a single emergency could make both exits inaccessible at the same time. What is a general rule of thumb to calculate the minimum distance between exits for an unsprinklered facility?

Answerd' (distance) must be at least 1/2 D (the diagonal measurement of the building or space served by the exits.)

ARE 4.0 exam prep: SD

Comments

  1. Isn't this one 1/3 of the diagonal distance, not 1/2?

    ReplyDelete
  2. If the building is sprinklered, then yes. If not, still 1/2. Although intended for nyc code specific issues, this nyc building department presentation has some good graphic illustrations of egress. www.nyc.gov/html/dob/downloads/pdf/means_of_egress_presentation.pdf

    ReplyDelete

Post a Comment

Try These Too!

Interior Glazing

Safety glazing (tempered glass, laminated glass or impact resistant plastic) is not required at this interior window (18sf glazed area). Which of these satisfies conditions for using non-safety glazing? A. Within 36 inches horizontally of a walking surface B. Bottom edge is less than 60" above the plane of the adjacent walking surface C. 1 1/2 in protective bar between 34 and 38 inches on accessible side D. Exposed area of the pane is greater than 9 sf Answer C. 1 1/2 inch protective bar between 34-38 inches on accessible side. In this case, safety glazing is not required. ARE 4.0 exam prep: BDCS

Thermal insulation

Which of the following types of thermal insulation can be blown into wall or ceiling cavities with least difficulty, but contains no adhesive properties? I. Cellulose II. Rock wool III. Vermiculite IV. Mineral wool V. Straw VI. Polyicynene Answer I, II and III are loose-fill types of insulation that can be blown. IV comes in batts, V can come in boards or bales, VI is a spray-foam that adheres to the cavity. ARE 4.0 exam prep: BS

Heat gain calculation

Which lighting produces a 654.72 Btu/hr heat gain? A. 4x 40 watt fluorescent bulbs B. 2 x 75 watt incandescent C. 12 x 12 watt LEDs Answer (1 watt = 3.41 Btu/hr) A. 4x40 watts x 1.2 (for ballast) x 3.41 Btu/hr ARE 4.0 exam prep: BS