Successful daylighting can be achieved with an effective aperture (EA) of between 0.20 - 0.30. Which of the following provides an EA within this range?
1. 105 sf net glazing area with visible light transmittance (VLT) of 0.38, in a space whose gross exterior wall area is 150 sf
2. 100 sf net glazing area with VLT of 0.53, in a space whose gross exterior wall area is 200 sf
3. 42 sf net glazing area with VLT of 0.88, in a space whose gross exterior wall area is 140 sf

AnswerEA = VT x WWR. EA = 0.264 - 0.266 - each of these windows offers the same effective aperture within the ideal value range.

Comments

Try These Too!

Calculate Luminance

A typical 60-watt standard frosted incandescent bulb outputs 890 lumens for an efficacy ratio of about 15 lumens per watt. As an A19, its shape is spherical. What is the its calculated luminance? A. 25,115 cd/in² B. 25.115 cd/ft² C. 25,115 cd/m² D. Indeterminate, missing variable. Answer If 1 candela (cd) = 4 ∏ lumens (lm), 890 x 1cd/4∏ = 71 cd, A19 = 19/8 = 2.375 in or 60mm diameter (= 30mm radius), L = intensity / projected area, 71 cd / ∏ r² = 71/ 3.14 x (.03m)² = 25,115 cd/m² ARE 4.0 exam prep: BS

Characteristics of form

Which example illustrates a regular ordering of elements producing RHYTHM? A B C D Answer Answer is C. A = proportion, B = symmetry, D = balance ARE 4.0 exam prep: PPP

Roof pitch

Which one of the following slopes in this illustration corresponds with an 8:12 pitch roof? A. 45° B. 36.87° C. 33.69° D. 26.57°