Vapor retarders



In this section, a ceiling assembly separates the attic space above from the room interior below. If the building is located in Lewisville, Texas (hot-humid zone), where is the predicted location of condensation and what is the predicted condition of the gypsum board in this assembly? (Select 2 from the following)

A. outside face of vapor retarder
B. inside face of vapor retarder
C. gypsum board will be wet
D. gypsum board will be dry



Answer: A. and C. As Lewisville is a hot-humid location, expect the room interior to be cooled by air-conditioning. Kraft paper facing acts as a vapor retarder with predictable condensation on the outside face, but this is faced on both sides - so the gyp. board will be wet. The vapor retarder should only be located outside of the insulation or between the insulation and the ventilated attic space.

Visit the PPD-PDD page for more study resources!

Reference tip: read a paper about air vs vapor barriers here from conference session E11: Performance of the Building Enclosure of the 2008 Best 1 Conference BEST = Building Enclosure Science & Technology from National Institute of Building Sciences.

Comments

  1. Updated the links to the Building Enclosure paper & NIBS BEST Conferences...

    ReplyDelete

Post a Comment

Try These Too!

Bolted connections

What is the minimum spacing of bolts specified by AISC? and preferred spacing? A. 1 1/4 times the diameter of the bolt; 2 times preferred B. 1 3/4 times the diameter of the bolt; 2 1/4 times preferred C. 2 1/3 times the diameter of the bolt; 2 2/3 times preferred D. 2 2/3 times the diameter of the bolt; 3 times preferred E. 3 times the diameter of the bolt; 3.25 times preferred

Brick bonds

What distinguishes the English Bond pattern from the Dutch Bond pattern in this image? Answer In the English Bond, stretchers are aligned; In the Dutch (cross), stretchers move by a half each course (not aligned). ARE 4.0 exam prep: BDCS

Collector walks

Walks next to parking areas where vehicles are able to overhang the walk should be a minimum width. What is this minimum in feet? A. 3 feet B. 4 feet C. 5 feet D. 6 feet Answer These walks should be 6 ft (D.) minimum in width. ARE 4.0 exam prep: SPD