Irregularity

Identify the condition of vertical irregularity in this illustration.

AnswerIn-plane discontinuity in vertical lateral-force resisting elements - that is offset of structural elements. Shear walls transfer loads to the foundation, but the capacity to do so is interrupted in this condition of random windows and openings.
ARE 4.0 exam prep: SS

Comments

Try These Too!

Fire detection

Which of the following detector types can detect smoke or a smoldering fire that has not yet burst into flames? A. Ionization B. Rise-of-temperature C. Photoelectric D. Flame detectors

Roof pitch

Which one of the following slopes in this illustration corresponds with an 8:12 pitch roof? A. 45° B. 36.87° C. 33.69° D. 26.57°

Elevator bank layouts

An office building has an elevator bank with 4 elevators where 2 cabs side-by-side are arranged opposite the other 2. Each of the elevators is 3500-pound capacity with an interior cab dimension of 6'8" x 5'4". What is the recommended corridor width at this group? A. 8 feet B. 9 feet C. 11 feet D. 12 feet Answer C. 11 feet. At 1.5-2 times the car depth (5'4), this could be a range, but 10 feet is a minimum for groups of 4 or more. Therefore C is the best choice. ARE 4.0 exam prep: BDCS