Interior Glazing

Safety glazing (tempered glass, laminated glass or impact resistant plastic) is not required at this interior window (18sf glazed area). Which of these satisfies conditions for using non-safety glazing?
A. Within 36 inches horizontally of a walking surface
B. Bottom edge is less than 60" above the plane of the adjacent walking surface
C. 1 1/2 in protective bar between 34 and 38 inches on accessible side
D. Exposed area of the pane is greater than 9 sf

AnswerC. 1 1/2 inch protective bar between 34-38 inches on accessible side. In this case, safety glazing is not required.
ARE 4.0 exam prep: BDCS

Comments

Try These Too!

Structural forces

Choose a term that best identifies the type of force shown in this diagram - A. collinear B. concurrent C. nonconcurrent D. noncoplanar

Bolted connections

What is the minimum spacing of bolts specified by AISC? and preferred spacing? A. 1 1/4 times the diameter of the bolt; 2 times preferred B. 1 3/4 times the diameter of the bolt; 2 1/4 times preferred C. 2 1/3 times the diameter of the bolt; 2 2/3 times preferred D. 2 2/3 times the diameter of the bolt; 3 times preferred E. 3 times the diameter of the bolt; 3.25 times preferred

Roof pitch

Which one of the following slopes in this illustration corresponds with an 8:12 pitch roof? A. 45° B. 36.87° C. 33.69° D. 26.57°