As outlined in B101 (owner-architect agreement, article 3), which of the following are usual and customary services included in the Architect's Basic Services? choose 3
A. mechanical
B. structural
C. electrical
D. civil engineering
E. existing facilities surveys
Answerusual and customary A. mechanical, B. structural, and C. electrical services are part of the Architect's Basic Services. Civil and existing facilities surveys are additional services.
ARE 4.0 exam prep: CDS

Comments

Try These Too!

Characteristics of form

Which example illustrates a regular ordering of elements producing RHYTHM? A B C D Answer Answer is C. A = proportion, B = symmetry, D = balance ARE 4.0 exam prep: PPP

Refrigeration cycle

A water cooled liquid chiller (photo) performs which function in the refrigeration cycle for HVAC systems? A. thermal expansion valve, reducing pressure from the refrigerant's liquid state B. condenser cooling hot refrigerant with ambient air C. heat exchanger for liquid to cool air or equipment D. removes heat from liquid by vapor-compression or absorption refrigeration Answer D. removes heat from liquid by vapor-compression or absorption refrigeration. Industrial chillers may combine the chiller unit, condenser, pump station and expansion valve into a packaged unit. ARE 4.0 exam prep: BS

Clear Floor Area

What is the clear floor area required for this front approach at an accessible water fountain? (yellow dash line) A. 36 x 60 B. 36 x 48 C. 30 x 48 D. 30 x 60 Answer C. 30 x 48. Although set in an alcove, the depth of the recess is not 24 inches or greater, which requires a 36 inch clear width. ARE 4.0 exam prep: SPD