Match the flame spread and smoke developed index values with the corresponding wall & ceiling finish class:
flame spread 0-25
flame spread 26-75
flame spread 76-200
smoke developed 0-100
smoke developed 0-450
smoke developed >500

Class A =
Class B =
Class C =

AnswerA=flame 0-25, smoke 0-450; B=flame26-75, smoke 0-450; C=flame 76-200, smoke 0-450

ARE 4.0 exam prep: BCDS

Comments

Try These Too!

Building Efficiency

Convert the usable area of classrooms planned with medium efficiency level of new construction to the gross building area given the following model factors: Net Assignable Square Feet: 10,000, Space Factor: 1.5, Building Efficiency Ratio: 67%

Spec coordination

In case there is a discrepancy between specifications and the drawings, which takes precedence? Answer Neither, A201 considers these - quote - complementary and what is required by one shall be binding as if required by all.- unquote. ARE 4.0 exam prep: CDS