Skip to main content

Standing seam roof

Metal roof panels (interlocking metal sheets with a minimum weather exposure of 3 square feet) may have different minimum allowable slopes depending on whether they are lapped, nonsoldered with or without lap sealant applied. With applied lap sealant, what is the minimum units vertical : units horizontal?
A. 1/4 vertical in 12 units horizontal (2%)
B. 1/2 vertical in 12 units horizontal (4%)
C. 2 vertical in 12 units horizontal (17%)
D. 3 vertical in 12 units horizontal (25%)

AnswerB. 1/2:12 or 4% slope. Without lap sealant, it's 3:12

ARE 4.0 exam prep: BDCS

Resource tip: IBC Roof assemblies, metal roof panels - see 1502-1507

Comments

Try These Too!

Thermal insulation

Which of the following types of thermal insulation can be blown into wall or ceiling cavities with least difficulty, but contains no adhesive properties? I. Cellulose II. Rock wool III. Vermiculite IV. Mineral wool V. Straw VI. Polyicynene Answer I, II and III are loose-fill types of insulation that can be blown. IV comes in batts, V can come in boards or bales, VI is a spray-foam that adheres to the cavity. ARE 4.0 exam prep: BS

Efficient columns

The radius of gyration in the Y-Y axis would be equal to that in the X-X axis in an ideally efficient column. Which of the following sections are most appropriate for both heavy loads and for which many beam connections will be necessary? A. pipe column B. square tube column C. wide-flange column D. C-shape channel E. WT shapes Answer C. wide-flange column. Pipe & square tube columns are more ideal shapes, but are appropriate for light to moderate loads. The radius of gyration of wide-flange shapes can be nearly or close to equal. ARE 4.0 exam prep: SS

Elevator bank layouts

An office building has an elevator bank with 4 elevators where 2 cabs side-by-side are arranged opposite the other 2. Each of the elevators is 3500-pound capacity with an interior cab dimension of 6'8" x 5'4". What is the recommended corridor width at this group? A. 8 feet B. 9 feet C. 11 feet D. 12 feet Answer C. 11 feet. At 1.5-2 times the car depth (5'4), this could be a range, but 10 feet is a minimum for groups of 4 or more. Therefore C is the best choice. ARE 4.0 exam prep: BDCS