Skip to main content

Interior Finish

Which of the following items is included in IBCs definition of Interior Finish for application of flame spread rating limits which is based on occupancy and area of use as well as in sprinklered or unsprinklered buildings?
A. wainscoting
B. wood veneer paneling
C. chair rails
D. baseboards
E. textile wall coverings
AnswerABE are interior finishes, CD are considered trim which must have min. Class C flame-spread index (wood trim can't exceed 10% of its wall area).

ARE 4.0 exam prep: BDCS

Comments

Try These Too!

Bolted connections

What is the minimum spacing of bolts specified by AISC? and preferred spacing? A. 1 1/4 times the diameter of the bolt; 2 times preferred B. 1 3/4 times the diameter of the bolt; 2 1/4 times preferred C. 2 1/3 times the diameter of the bolt; 2 2/3 times preferred D. 2 2/3 times the diameter of the bolt; 3 times preferred E. 3 times the diameter of the bolt; 3.25 times preferred

Roof pitch

Which one of the following slopes in this illustration corresponds with an 8:12 pitch roof? A. 45° B. 36.87° C. 33.69° D. 26.57°

Fire detection

Which of the following detector types can detect smoke or a smoldering fire that has not yet burst into flames? A. Ionization B. Rise-of-temperature C. Photoelectric D. Flame detectors