An owner-architect contract has stipulated an adjustment in compensation for reviewing re-submittals beyond a specified number. Where is this corresponding model language exist in order to coordinate with the contractor's responsibilities?
0.00.00 The Architect's review of Contractor's submittals will be limited to examination of an initial submittal and ____________ (_____) resubmittals. The Owner is entitled to obtain reimbursement from the Contractor for amounts paid to the Architect for evaluation of additional resubmittals.

AnswerIt does not exist in the standard A201 general conditions of the contract for construction, and is recommended to be added to Section 3.12, as 3.12.11.

ARE 4.0 exam study: CDS

Comments

Try These Too!

Interior Glazing

Safety glazing (tempered glass, laminated glass or impact resistant plastic) is not required at this interior window (18sf glazed area). Which of these satisfies conditions for using non-safety glazing? A. Within 36 inches horizontally of a walking surface B. Bottom edge is less than 60" above the plane of the adjacent walking surface C. 1 1/2 in protective bar between 34 and 38 inches on accessible side D. Exposed area of the pane is greater than 9 sf Answer C. 1 1/2 inch protective bar between 34-38 inches on accessible side. In this case, safety glazing is not required. ARE 4.0 exam prep: BDCS

Thermal insulation

Which of the following types of thermal insulation can be blown into wall or ceiling cavities with least difficulty, but contains no adhesive properties? I. Cellulose II. Rock wool III. Vermiculite IV. Mineral wool V. Straw VI. Polyicynene Answer I, II and III are loose-fill types of insulation that can be blown. IV comes in batts, V can come in boards or bales, VI is a spray-foam that adheres to the cavity. ARE 4.0 exam prep: BS

Heat gain calculation

Which lighting produces a 654.72 Btu/hr heat gain? A. 4x 40 watt fluorescent bulbs B. 2 x 75 watt incandescent C. 12 x 12 watt LEDs Answer (1 watt = 3.41 Btu/hr) A. 4x40 watts x 1.2 (for ballast) x 3.41 Btu/hr ARE 4.0 exam prep: BS