Design occupant load

What is the design occupant load for a an office building floor with the following spaces:
21ft x 20ft non-fixed seating area allowing 7 sf of floor area per occupant, 30ft x 40ft business area of workstations allowing 100sf of floor area per occupant?



60+12 = 72 (as group B occupancy more than 50, 2 means of egress are required with each door's occupant load = 36.)

are-review.blogspot.com

Comments

Try These Too!

Calculate Luminance

A typical 60-watt standard frosted incandescent bulb outputs 890 lumens for an efficacy ratio of about 15 lumens per watt. As an A19, its shape is spherical. What is the its calculated luminance? A. 25,115 cd/in² B. 25.115 cd/ft² C. 25,115 cd/m² D. Indeterminate, missing variable. Answer If 1 candela (cd) = 4 ∏ lumens (lm), 890 x 1cd/4∏ = 71 cd, A19 = 19/8 = 2.375 in or 60mm diameter (= 30mm radius), L = intensity / projected area, 71 cd / ∏ r² = 71/ 3.14 x (.03m)² = 25,115 cd/m² ARE 4.0 exam prep: BS