Concrete form ties


Unless stainless steel ties are specified, ACI (American Concrete Institute) recommends patching, partially filling or plugging the finished depression / holes left by form ties in the concrete surface. Why?




To prevent corrosion of the tie or staining of the concrete surface.
are-review.blogspot.com

Comments

Try These Too!

Elevator bank layouts

An office building has an elevator bank with 4 elevators where 2 cabs side-by-side are arranged opposite the other 2. Each of the elevators is 3500-pound capacity with an interior cab dimension of 6'8" x 5'4". What is the recommended corridor width at this group? A. 8 feet B. 9 feet C. 11 feet D. 12 feet Answer C. 11 feet. At 1.5-2 times the car depth (5'4), this could be a range, but 10 feet is a minimum for groups of 4 or more. Therefore C is the best choice. ARE 4.0 exam prep: BDCS

Fire detection

Which of the following detector types can detect smoke or a smoldering fire that has not yet burst into flames? A. Ionization B. Rise-of-temperature C. Photoelectric D. Flame detectors

Floor receptacles

To qualify as one of the required power receptacles in a dwelling, according to NEC, what is the maximum distance from the wall that this recessed or surface-mounted floor receptacle close to an exterior wall may be? Answer Less than or equal to 18 inches. Additional requirements apply, such as approved floor box housing, cover... ARE 4.0 exam prep: BS