Winchester Cathedral

The north transept of Winchester cathedral (Hampshire, England) is an example of this medieval form of architecture (choose 2) A. romanesque B. gothic C. norman D. perpendicular E. decorated F. early english Answer A and C -unlike the remainder of Winchester (other answers are all gothic period), this part is romanesque (norman) begun in 1079 with rounded arches and block capitals. ARE 4.0 exam prep: PPP

Unit masonry

Which of the following types of unit masonry is composed of an enriched clay that has been fired at a high temperature, is often used for cladding, does not off gas and is noncombustible? (choose 2) A. Brick B. Concrete block C. Clay tile D. Ceramic veneer E. Terra cotta F. Gypsum block Answer D and E. Terra cotta in panels used for exterior cladding is also known as ceramic veneer. ARE 4.0 exam prep: BDCS

Accessible signage

Per ANSI 117.1, what is the minimum and maximum height, based on the uppercase letter 'I', of the characters in "WOMEN" for this signage? Answer Minimum 5/8 inch and maximum 2 inches. ARE 4.0 exam prep

Energy code-language docs

Two standards currently used to specify R-values on commercial roofing are both issued by which organization? A. DOE B. ASHRAE C. ASTM D. IRC Answer B. ASHRAE issues Standard 90.1 and proposed Standard 189. ARE 4.0 exam prep: BS

Thermal conductance

The basic unit of conductance of a 2" thick insulation board is given as A. k-value B. C-value C. Btu's D. None of the above Answer B. C-value: a unit of conductance, depends on the thickness of a material. k-value refers to conductivity of material 1 inch thickness. C-value = K-value / thickness. ARE 4.0 exam prep: BDCS

Building code goals

What primary and secondary goals of building codes are served by sprinkler system provisions? Answer protection of human life (life safety) and protection of property. ARE 4.0 exam prep: PPP

Soil characteristics

The texture of soil indicates its A. drainage quality, fertility and amount of organic matter B. workability and ability to retain water C. consistency D. availability of minerals Answer B. workability and ability to retain water. (A=color, C=structure, D=depth) ARE 4.0 exam prep: SPD

Floor receptacles

To qualify as one of the required power receptacles in a dwelling, according to NEC, what is the maximum distance from the wall that this recessed or surface-mounted floor receptacle close to an exterior wall may be? Answer Less than or equal to 18 inches. Additional requirements apply, such as approved floor box housing, cover... ARE 4.0 exam prep: BS

Bridging documents delivery

What is the difference between DGIs and CDs in the bridging method of project delivery? Answer Design Guide Illustrations are prepared by the owner's design consultant and are a component of the Bridging Contract Documents. Contract Documents are final working dwgs prepared by the contractor's AE team. ARE 4.0 exam prep: PPP

Construction type

Fire-resistance rating requirements listed in IBC Table 601 list major building elements based on construction classification. Match these two criteria correctly, choose 2 A. Type IB = roof construction 1 1/2 hrs B. Type IIB = exterior bearing walls 1 hr C. Type IIIA = structural frame 1 hr D. Type VB = floor construction 1 hr E. Type IVHT = exterior bearing walls 2 hr Answer C. and E. are correct. HT = heavy timber. ARE 4.0 exam prep: BDCS Reference tip:  Find the online version of Table 601 in this discussion paper here

Public facilities

Public toilets required in public facilities may be located on the story above or below the space served by the toilets and may be part of a large floor plate. Patrons or visitors must travel a distance not to exceed how many feet? A. 100 ft B. 200 ft C. 300 ft D. 400 ft E. 500 ft Answer E. 500 feet. Also, if the path of travel is not accessible, alternate accessible facilities must be provided. ARE 4.0 exam prep: SD

AIA doc series

In which AIA document series would one find the Contractor - Subcontractor contract form? A. A-series B. B-series C. C-series D. D-series E. E-series F. G-series Answer A. A-series (A401-2007). ARE 4.0 exam prep: CDS

Plywood double-post!

Why are the plies in plywood turned at right angles in each successive layer? Answer This helps plywood panels to have a high degree of resistance to splitting. In this image, the panel consists of 3 plies. What is the name of each ply? Answer Face+Core+Face. In 5 or 7 ply panels, the core is sandwiched by crossbacks with a face and a back ply. ARE 4.0 exam prep: BDCS

Soil bearing capacity

One method to improve soil bearing capacity involves addition of fill to existing soil, then letting the soil settle over time, which is called: A. Compaction B. Densification C. Surcharging D. Mixing E. Fill Answer C. Surcharging. ARE 4.0 exam prep: SPD

Contract bonds

Which type of contract bonds are required on most public works projects? I. performance II. bid III. payment A. II B. I and II C. I and III D. I, II and III Answer D. I, II and III. Bid (ensure lowest bidder enters into contract), Performance (guarantee contract is completed), Payment (guarantee payment to labor and suppliers. ARE 4.0 exam prep: CDS

Weld Joint Types